TOP Contributors

  1. MIKROE (2656 codes)
  2. Alcides Ramos (353 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136803 times)
  2. FAT32 Library (69983 times)
  3. Network Ethernet Library (55951 times)
  4. USB Device Library (46274 times)
  5. Network WiFi Library (41892 times)
  6. FT800 Library (41188 times)
  7. GSM click (28990 times)
  8. PID Library (26420 times)
  9. mikroSDK (26375 times)
  10. microSD click (25382 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Hydrogen click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.13

mikroSDK Library: 2.0.0.0

Category: Gas

Downloaded: 72 times

Not followed.

License: MIT license  

Hydrogen click carries an MQ-8 sensor for hydrogen (H2). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Hydrogen click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Hydrogen click" changes.

Do you want to report abuse regarding "Hydrogen click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Hydrogen click

Hydrogen click carries an MQ-8 sensor for hydrogen (H2). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air.

hydrogen_click.png

click Product page


Click library

  • Author : Jelena Milosavljevic
  • Date : Jun 2021.
  • Type : ADC type

Software Support

We provide a library for the Hydrogen Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Hydrogen Click driver.

Standard key functions :

  • hydrogen_cfg_setup Config Object Initialization function.

    void hydrogen_cfg_setup ( hydrogen_cfg_t *cfg );
  • hydrogen_init Initialization function.

    HYDROGEN_RETVAL hydrogen_init ( hydrogen_t *ctx, hydrogen_cfg_t *cfg );

Example key functions :

  • hydrogen_read_an_pin_value This function reads results of AD conversion of the AN pin.

    err_t hydrogen_read_an_pin_value ( hydrogen_t *ctx, uint16_t *data_out );
  • hydrogen_read_an_pin_voltage This function reads results of AD conversion of the AN pin and converts them to proportional voltage level.

    err_t hydrogen_read_an_pin_voltage ( hydrogen_t *ctx, float *data_out );

Example Description

The demo application shows the reading of the adc values given by the sensors.

The demo application is composed of two sections :

Application Init

Configuring clicks and log objects.


void application_init ( void ) {
    log_cfg_t log_cfg;  /**< Logger config object. */
    hydrogen_cfg_t hydrogen_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.

    hydrogen_cfg_setup( &hydrogen_cfg );
    HYDROGEN_MAP_MIKROBUS( hydrogen_cfg, MIKROBUS_1 );
    if ( hydrogen_init( &hydrogen, &hydrogen_cfg ) == ADC_ERROR ) {
        log_error( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }
    log_info( &logger, " Application Task " );
}

Application Task

Reads the adc value and prints in two forms (DEC and HEX).


void application_task ( void ) {
    uint16_t hydrogen_an_value = 0;

    if ( hydrogen_read_an_pin_value ( &hydrogen, &hydrogen_an_value ) != ADC_ERROR ) {
        log_printf( &logger, " ADC Value : %u\r\n", hydrogen_an_value );
    }

    float hydrogen_an_voltage = 0;

    if ( hydrogen_read_an_pin_voltage ( &hydrogen, &hydrogen_an_voltage ) != ADC_ERROR ) {
        log_printf( &logger, " AN Voltage : %.3f[V]\r\n\n", hydrogen_an_voltage );
    }

    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Hydrogen

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

Ambient click

0

Ambient click carries the Melexis MLX75305 IC. It’s a CMOS integrated optical sensor that consists of a photodiode, a transimpendance amplifier, and an output transistor.

[Learn More]

IR Sense 3 click

5

IR Sense 3 Click is the infrared sensor Click board, designed to be used for the short range IR sensing applications. Unlike other pyroelectric sensors, it is able to sense environmental heat changes up to 1m, even through the glass.

[Learn More]

Color click

0

Simple demonstration of using TCS3471 color sensor.

[Learn More]