TOP Contributors

  1. MIKROE (2657 codes)
  2. Alcides Ramos (354 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136888 times)
  2. FAT32 Library (70027 times)
  3. Network Ethernet Library (56002 times)
  4. USB Device Library (46308 times)
  5. Network WiFi Library (41934 times)
  6. FT800 Library (41212 times)
  7. GSM click (29019 times)
  8. PID Library (26434 times)
  9. mikroSDK (26401 times)
  10. microSD click (25386 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Methane click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Gas

Downloaded: 102 times

Not followed.

License: MIT license  

Methane click carries an MQ-4 sensor for methane (CH4). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Methane click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Methane click" changes.

Do you want to report abuse regarding "Methane click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Methane click

Methane click carries an MQ-4 sensor for methane (CH4). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air.

methane_click.png

click Product page


Click library

  • Author : Stefan Ilic
  • Date : Jun 2021.
  • Type : ADC type

Software Support

We provide a library for the Methane Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Methane Click driver.

Standard key functions :

  • methane_cfg_setup Config Object Initialization function.

    void methane_cfg_setup ( methane_cfg_t *cfg );
  • methane_init Initialization function.

    METHANE_RETVAL methane_init ( methane_t *ctx, methane_cfg_t *cfg );
  • methane_default_cfg Click Default Configuration function.

    void methane_default_cfg ( methane_t *ctx );

Example key functions :

  • methane_read_an_pin_value Methane read AN pin value function.

    err_t methane_read_an_pin_value ( methane_t *ctx, uint16_t *data_out );
  • methane_read_an_pin_voltage Methane read AN pin voltage level function.

    err_t methane_read_an_pin_voltage ( methane_t *ctx, float *data_out );

Example Description

The demo application shows the reading of the adc values given by the sensors.

The demo application is composed of two sections :

Application Init

Configuring clicks and log objects.


void application_init ( void ) {
    log_cfg_t log_cfg;  /**< Logger config object. */
    methane_cfg_t methane_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.

    methane_cfg_setup( &methane_cfg );
    METHANE_MAP_MIKROBUS( methane_cfg, MIKROBUS_1 );
    if ( methane_init( &methane, &methane_cfg ) == ADC_ERROR ) {
        log_error( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }
    log_info( &logger, " Application Task " );
}

Application Task

Reads the adc value and prints in two forms adc value and voltage.


void application_task ( void ) {
    uint16_t methane_an_value = 0;

    if ( methane_read_an_pin_value ( &methane, &methane_an_value ) != ADC_ERROR ) {
        log_printf( &logger, " ADC Value : %u\r\n", methane_an_value );
    }

    float methane_an_voltage = 0;

    if ( methane_read_an_pin_voltage ( &methane, &methane_an_voltage ) != ADC_ERROR ) {
        log_printf( &logger, " AN Voltage : %.3f[V]\r\n\n", methane_an_voltage );
    }

    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Methane

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

mikromedia for PIC18FK - Examples

0

Set of examples for mikromedia for PIC18FK. Provided examples demonstrate working with mikromedia's various features and modules: - Accelerometer - MMC SD card - MP3 - Serial Flash - TFT - Touch Panel - USB UART

[Learn More]

DAC 9 click

0

DAC 9 Click is a compact add-on board that contains a fully-featured, highly accurate digital-to-analog converter. This board features the DAC80501, a 16-bit voltage-output digital-to-analog converter with precision internal reference from Texas Instruments. It supports both I2C and SPI serial interface and offers a linearity of < 1 LSB. It also includes a 2.5V internal reference, giving full-scale output voltage ranges of 1.25V, 2.5V, or 5V, incorporate a Power-On Reset function, consume a low current of 1mA, and include a Power-Down feature that reduces current consumption to typically 15μA at 5V.

[Learn More]

Thermo 5 click

12

THERMO 5 click measures temperature in default range of 0°C to 127°C and extended range of -64°C to 191°C with ±1°C accuracy. It carries the EMC1414 temperature sensor. The click is designed to run on a 3.3V power supply.

[Learn More]