TOP Contributors

  1. MIKROE (2663 codes)
  2. Alcides Ramos (357 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (137069 times)
  2. FAT32 Library (70199 times)
  3. Network Ethernet Library (56082 times)
  4. USB Device Library (46395 times)
  5. Network WiFi Library (42013 times)
  6. FT800 Library (41348 times)
  7. GSM click (29108 times)
  8. mikroSDK (26544 times)
  9. PID Library (26486 times)
  10. microSD click (25483 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Water Detect 2 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.4

mikroSDK Library: 2.0.0.0

Category: Miscellaneous

Downloaded: 35 times

Not followed.

License: MIT license  

Water Detect 2 Click is a compact add-on board that can detect the presence/flow of a liquid in a clear tube. This board features the OPB350L250, a tube liquid sensor from TT Electronics. Water Detect 2 Click has multiple output states and can recognize fluid present, no fluid present, and no tube present. This sensor excepts 1/4” tubing (6.3mm) as an outside diameter of the clear tubes, regardless of the direction of the liquid’s flow.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Water Detect 2 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Water Detect 2 click" changes.

Do you want to report abuse regarding "Water Detect 2 click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Water Detect 2 click

Water Detect 2 Click is a compact add-on board that can detect the presence/flow of a liquid in a clear tube. This board features the OPB350L250, a tube liquid sensor from TT Electronics. Water Detect 2 Click has multiple output states and can recognize fluid present, no fluid present, and no tube present. This sensor excepts 1/4” tubing (6.3mm) as an outside diameter of the clear tubes, regardless of the direction of the liquid’s flow.

waterdetect2_click.png

click Product page


Click library

  • Author : Nenad Filipovic
  • Date : Jul 2023.
  • Type : GPIO type

Software Support

We provide a library for the Water Detect 2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Water Detect 2 Click driver.

Standard key functions :

  • waterdetect2_cfg_setup Config Object Initialization function.

    void waterdetect2_cfg_setup ( waterdetect2_cfg_t *cfg );
  • waterdetect2_init Initialization function.

    err_t waterdetect2_init ( waterdetect2_t *ctx, waterdetect2_cfg_t *cfg );
  • waterdetect2_default_cfg Click Default Configuration function.

    void waterdetect2_default_cfg ( waterdetect2_t *ctx );

Example key functions :

  • waterdetect2_get_fluid_status Water Detect 2 get fluid status function.

    uint8_t waterdetect2_get_fluid_status ( waterdetect2_t *ctx );
  • waterdetect2_enable Water Detect 2 enable function.

    void waterdetect2_enable ( waterdetect2_t *ctx );
  • waterdetect2_disable Water Detect 2 disable function.

    void waterdetect2_disable ( waterdetect2_t *ctx );

Example Description

This library contains API for Water Detect 2 Click driver. Water Detect 2 click is used for detecting water and other electroconductive liquids.

The demo application is composed of two sections :

Application Init

Initializes driver and performs the default configuration.

void application_init ( void ) 
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    waterdetect2_cfg_t waterdetect2_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    waterdetect2_cfg_setup( &waterdetect2_cfg );
    WATERDETECT2_MAP_MIKROBUS( waterdetect2_cfg, MIKROBUS_1 );
    if ( DIGITAL_OUT_UNSUPPORTED_PIN == waterdetect2_init( &waterdetect2, &waterdetect2_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }

    waterdetect2_default_cfg( &waterdetect2 );
    log_info( &logger, " Application Task " );
}

Application Task

Reads fluid presence status and determines if there is fluid presence or not.

void application_task ( void ) 
{
    uint8_t fluid_status = waterdetect2_get_fluid_status( &waterdetect2 );
    if ( fluid_status != fluid_status_old )
    {
        if ( WATERDETECT2_FLUID_DETECTED == fluid_status )
        {
            log_printf( &logger, " Fluid present! \r\n" );
        }
        else
        {
            log_printf( &logger, " No fluid present. \r\n" );
        }
        log_printf( &logger, "------------------- \r\n" );
        fluid_status_old = fluid_status;
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.WaterDetect2

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

IR Reflect click

6

IR reflect click carries a GP2S700HCP reflective photointerrupter. The infrared beam from the emitter gets bounced back to the receiver when an object is placed within the detecting range of the sensor (optimal range is 3mm).

[Learn More]

MPU IMU click

0

Simple demonstration of using MPU 6000 6-axis motion device Example reads the 3-axis gyroscope, a 3-axis accelerometer and temperature sensor data and writes them to UART.

[Learn More]

Thermo 11 click

0

Thermo 11 Click is a Click board™ equipped with the sensor IC, which can digitize temperature measurements between -55°C and +150°C so that the temperature measurement data can be processed by the host MCU.

[Learn More]