TOP Contributors

  1. MIKROE (2659 codes)
  2. Alcides Ramos (356 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136992 times)
  2. FAT32 Library (70106 times)
  3. Network Ethernet Library (56026 times)
  4. USB Device Library (46345 times)
  5. Network WiFi Library (41962 times)
  6. FT800 Library (41280 times)
  7. GSM click (29051 times)
  8. mikroSDK (26489 times)
  9. PID Library (26447 times)
  10. microSD click (25413 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

pH 2 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.5

mikroSDK Library: 2.0.0.0

Category: Environmental

Downloaded: 55 times

Not followed.

License: MIT license  

pH 2 Click is a compact add-on board used to determine the alkalinity or acidity of a sample. This board features the MCP607, a low-bias current Op Amp from Microchip, performing level shifting and high-input impedance buffering in a single-supply pH-electrode circuit.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "pH 2 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "pH 2 click" changes.

Do you want to report abuse regarding "pH 2 click".

  • Information
  • Comments (0)

mikroSDK Library Blog


pH 2 click

pH 2 Click is a compact add-on board used to determine the alkalinity or acidity of a sample. This board features the MCP607, a low-bias current Op Amp from Microchip, performing level shifting and high-input impedance buffering in a single-supply pH-electrode circuit.

ph2_click.png

click Product page


Click library

  • Author : Stefan Ilic
  • Date : Jan 2023.
  • Type : ADC/I2C type

Software Support

We provide a library for the pH 2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for pH 2 Click driver.

Standard key functions :

  • ph2_cfg_setup Config Object Initialization function.

    void ph2_cfg_setup ( ph2_cfg_t *cfg );
  • ph2_init Initialization function.

    err_t ph2_init ( ph2_t *ctx, ph2_cfg_t *cfg );

Example key functions :

  • ph2_calibrate Ph 2 calibrate function.

    err_t ph2_calibrate ( ph2_t *ctx, float pH_value );
  • ph2_calculate_ph Ph 2 calculate pH value function.

    err_t ph2_calculate_ph ( ph2_t *ctx, float *pH_value );
  • ph2_calibrate_offset Ph 2 calibrate offset function.

    void ph2_calibrate_offset ( ph2_t *ctx );

Example Description

This library contains API for pH 2 Click driver. The library initializes and defines the I2C bus drivers or ADC drivers to read data from pH probe.

The demo application is composed of two sections :

Application Init

Initializes the driver and performs offset calibration, as well as calibration in pH-neutral substance.


void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    ph2_cfg_t ph2_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    ph2_cfg_setup( &ph2_cfg );
    PH2_MAP_MIKROBUS( ph2_cfg, MIKROBUS_1 );
    err_t init_flag = ph2_init( &ph2, &ph2_cfg );
    if ( ( ADC_ERROR == init_flag ) || ( I2C_MASTER_ERROR == init_flag ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }

    log_printf( &logger, " ================================ \r\n" );
    log_printf( &logger, "     Performing calibration       \r\n" );
    log_printf( &logger, " ================================ \r\n" );
    log_printf( &logger, " Disconect BNC connector, \r\n" );
    log_printf( &logger, "    short-circuit it, \r\n" );
    log_printf( &logger, " adjust offset potentiometer \r\n" );
    log_printf( &logger, " ================================ \r\n" );
    log_printf( &logger, " STAT1 - turn clockwise \r\n" );
    log_printf( &logger, " STAT2 - turn counter-clockwise \r\n" );
    log_printf( &logger, " ================================ \r\n" );

    ph2_calibrate_offset( &ph2 );

    log_printf( &logger, " Calibration completed \r\n" );
    log_printf( &logger, " ================================ \r\n" );

    log_printf( &logger, " Connect probe back \r\n" );
    log_printf( &logger, " ================================ \r\n" );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    log_printf( &logger, "  Place probe into pH  \r\n" );
    log_printf( &logger, " neutral substance for \r\n" );
    log_printf( &logger, " mid point calibration \r\n" );
    log_printf( &logger, " ================================ \r\n" );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    log_printf( &logger, " Starting calibration  \r\n" );
    log_printf( &logger, " ================================ \r\n" );  

    ph2_calibrate( &ph2, 7 );

    log_printf( &logger, " Calibration done!  \r\n" );
    log_printf( &logger, " ================================ \r\n" ); 

    log_info( &logger, " Application Task " );
    log_printf( &logger, " ================================ \r\n" ); 
}

Application Task

This example demonstrates the use of the pH 2 Click board by reading pH value of the substance where probe is placed.


void application_task ( void ) 
{
    float pH_val = 0;
    ph2_calculate_ph( &ph2, &pH_val );
    log_printf( &logger, " pH value: %.3f \r\n", pH_val );
    log_printf( &logger, " ================================ \r\n" ); 
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.pH2

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

Bargraph 2 click

0

BarGraph 2 click is a 10-segment bar graph display click, which uses a high-quality, multicolor bar graph LED display. The bar graph display is a very popular device for displaying various properties, whether it be an audio level, current/voltage level, position of the encoder, and generally any property that can be displayed in a form of a bar graph.

[Learn More]

Power/Reset click

0

Power/Reset Click is equipped with two capacitive touch pads on a single click board™.

[Learn More]

NFC Extend click

0

NFC Extend Click is NFC tag interface device with possibility of using any shape and size external antenna, offering 16 Kbit of electrically erasable programmable memory (EEPROM). This Click Board™ offer two communication interfaces.

[Learn More]