TOP Contributors

  1. MIKROE (2663 codes)
  2. Alcides Ramos (358 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (137111 times)
  2. FAT32 Library (70238 times)
  3. Network Ethernet Library (56129 times)
  4. USB Device Library (46434 times)
  5. Network WiFi Library (42080 times)
  6. FT800 Library (41390 times)
  7. GSM click (29118 times)
  8. mikroSDK (26564 times)
  9. PID Library (26503 times)
  10. microSD click (25487 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Hall Current 9 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Current sensor

Downloaded: 113 times

Not followed.

License: MIT license  

Hall Current 9 Click is a compact add-on board that contains the coreless current sensor corresponding to the safety standards. This board features the CQ3300, a high-speed response coreless current sensor using a Hall sensor that outputs the analog voltage proportional to the AC/DC from AKM Semiconductor.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Hall Current 9 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Hall Current 9 click" changes.

Do you want to report abuse regarding "Hall Current 9 click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Hall Current 9 click

Hall Current 9 Click is a compact add-on board that contains the coreless current sensor corresponding to the safety standards. This board features the CQ3300, a high-speed response coreless current sensor using a Hall sensor that outputs the analog voltage proportional to the AC/DC from AKM Semiconductor.

hall_current_9_click.png

click Product page


Click library

  • Author : Nenad Filipovic
  • Date : Dec 2020.
  • Type : I2C type

Software Support

We provide a library for the HallCurrent9 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on mikroE github account.

Library Description

> This library contains API for Hall Current 9 Click driver.

Standard key functions :

  • hallcurrent9_cfg_setup Config Object Initialization function.

    void hallcurrent9_cfg_setup ( hallcurrent9_cfg_t *cfg );
  • hallcurrent9_init Initialization function.

    HALLCURRENT9_RETVAL hallcurrent9_init ( hallcurrent9_t *ctx, hallcurrent9_cfg_t *cfg );
  • hallcurrent9_default_cfg Click Default Configuration function.

    void hallcurrent9_default_cfg ( hallcurrent9_t *ctx );

Example key functions :

  • hallcurrent9_read_adc Hall Current 9 I2C ADC reading function.

    err_t hallcurrent9_read_adc ( hallcurrent9_t *ctx, uint16_t *read_adc );
  • hallcurrent9_set_calibration Hall Current 9 set calibration function.

    err_t hallcurrent9_set_calibration ( hallcurrent9_t *ctx, hallcurrent9_calibration_data_t *adc_val );
  • hallcurrent9_get_current Hall Current 9 get current function.

    float hallcurrent9_get_current ( hallcurrent9_t *ctx, hallcurrent9_calibration_data_t *adc_val );

Examples Description

This library contains API for Hall Current 9 Click driver. The library contains drivers for measuring ADC values and for calculation current.

The demo application is composed of two sections :

Application Init

Initializes I2C driver and triggers the built-in calibration.

void application_init ( void ) {
    log_cfg_t log_cfg;                    /**< Logger config object. */
    hallcurrent9_cfg_t hallcurrent9_cfg;  /**< Click config object.  */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_printf( &logger, "\r\n" );
    log_printf( &logger, "--------------------------\r\n" );
    log_printf( &logger, "   Hall Current 9 click   \r\n" );
    log_printf( &logger, "--------------------------\r\n" );
    log_info( &logger, " Application Init " );

    // Click initialization.

    hallcurrent9_cfg_setup( &hallcurrent9_cfg );
    HALLCURRENT9_MAP_MIKROBUS( hallcurrent9_cfg, MIKROBUS_1 );
    err_t init_flag = hallcurrent9_init( &hallcurrent9, &hallcurrent9_cfg );
    if ( init_flag == I2C_MASTER_ERROR ) {
        log_error( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }

    log_printf( &logger, "---------------------------\r\n" );
    log_printf( &logger, "        Calibration        \r\n" );
    log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
    log_printf( &logger, "> Turn OFF the Power unit <\r\n" );
    log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
    log_printf( &logger, "  In the following 5 sec.  \r\n" );
    log_printf( &logger, " turn OFF the Power Supply \r\n" );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );

    log_printf( &logger, "-------------------------\r\n" );
    log_printf( &logger, "    Start calibration    \r\n" );

    if ( hallcurrent9_set_calibration( &hallcurrent9, &avg_adc_data ) == HALLCURRENT9_OK ) {
        log_printf( &logger, "---------------------------\r\n" );
        log_printf( &logger, "    Calibration  Done    \r\n" );
        Delay_ms ( 1000 );    
    }

    log_printf( &logger, "---------------------------\r\n" );
    log_printf( &logger, "    Start measurements :   \r\n" );
    log_printf( &logger, "---------------------------\r\n" );
}

Application Task

This is an example that demonstrates the use of the Hall Current 9 click board. In this example, we read and display the ADC and current ( mA ) data. Results are being sent to the Usart Terminal where you can track their changes.

void application_task ( void ) {   
    log_printf( &logger, "--------------------------\r\n", adc_data );
    hallcurrent9_read_adc( &hallcurrent9, &adc_data );
    log_printf( &logger, "   ADC     : %d \r\n", adc_data );

    current = hallcurrent9_get_current( &hallcurrent9, &avg_adc_data );
    log_printf( &logger, "   Current : %.2f mA \r\n", current );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on mikroE github account.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.HallCurrent9

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all Mikroelektronika compilers.


ALSO FROM THIS AUTHOR

PAC1954 click

0

PAC1954 Click is a compact add-on board that contains an energy monitoring solution. This board features the PAC1954, a four-channel DC power/energy monitor from Microchip Technology. It uses real-time calibration to minimize offset and gain errors with no input filters required for this device.

[Learn More]

RTK Base click

0

RTK Base Click is a compact add-on board used to improve the positional accuracy of the compatible RTK Rover board. This board features Quectel’s LG69TASMD, a dual-band multi-constellation GNSS module featuring a high-performance and high-reliability positioning engine. This module carries an RTK base station function by calculating and transmitting differential correction data via radio to allow the roving GPS to correct its position. It features the fifth generation of STMicroelectronics® positioning receiver platform with 80 tracking and four fast acquisition channels, supports up to 4 concurrent global constellations (GPS, QZSS, Galileo, and BDS) alongside RTCM 3.x protocol and commonly used UART interface.

[Learn More]

RAQ click

5

RAQ Click is a compact add-on board targeted for use in refrigeration air quality (RAQ) applications. This board features the ZMOD4450, a gas sensor module designed for detecting gases associated with food ripening or rotting from Renesas Electronics Corporation.

[Learn More]