TOP Contributors

  1. MIKROE (2663 codes)
  2. Alcides Ramos (358 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (137096 times)
  2. FAT32 Library (70236 times)
  3. Network Ethernet Library (56122 times)
  4. USB Device Library (46434 times)
  5. Network WiFi Library (42073 times)
  6. FT800 Library (41384 times)
  7. GSM click (29116 times)
  8. mikroSDK (26562 times)
  9. PID Library (26489 times)
  10. microSD click (25487 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

CAN Isolator click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: CAN

Downloaded: 121 times

Not followed.

License: MIT license  

CAN Isolator click provides isolated CAN communication. It carries the ADM3053 signal and power isolated CAN transceiver with an integrated isolated DC-to-DC converter.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "CAN Isolator click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "CAN Isolator click" changes.

Do you want to report abuse regarding "CAN Isolator click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


CAN Isolator click

CAN Isolator click provides isolated CAN communication. It carries the ADM3053 signal and power isolated CAN transceiver with an integrated isolated DC-to-DC converter.

canisolator_click.png

click Product page


Click library

  • Author : MikroE Team
  • Date : Jan 2020.
  • Type : UART type

Software Support

We provide a library for the CanIsolator Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for CanIsolator Click driver.

Standard key functions :

  • Config Object Initialization function.

    void canisolator_cfg_setup ( canisolator_cfg_t *cfg );

  • Initialization function.

    CANISOLATOR_RETVAL canisolator_init ( canisolator_t ctx, canisolator_cfg_t cfg );

  • Click Default Configuration function.

    void canisolator_default_cfg ( canisolator_t *ctx );

Example key functions :

  • Generic multi write function.

    void canisolator_generic_multi_write ( canisolator_t ctx, canisolator_data_t data_buf, uart_length_t len );

  • Generic multi read function.

    void canisolator_generic_multi_read ( canisolator_t ctx, canisolator_data_t data_buf, uart_length_t len );

  • Generic single read function.

    canisolator_data_t canisolator_generic_single_read ( canisolator_t *ctx );

  • Generic single write function.

    void canisolator_generic_single_write ( canisolator_t *ctx, canisolator_data_t tx_data );

Examples Description

This is a example which demonstrates the use of Can Isolator Click board.

The demo application is composed of two sections :

Application Init

Configuring clicks and log objects.


void application_init ( void )
{
    log_cfg_t log_cfg;
    canisolator_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_printf( &logger, "---- Application Init ----\r\n" );

    //  Click initialization.

    canisolator_cfg_setup( &cfg );
    CANISOLATOR_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    canisolator_init( &canisolator, &cfg );

    log_printf( &logger, "---------------------\r\n" );
    log_printf( &logger, " CAN Isolator  Click\r\n" );
    log_printf( &logger, "---------------------\r\n" );
    Delay_ms ( 100 );
}

Application Task

Checks if new data byte has received in RX buffer ( ready for reading ) and if ready than reads one byte from RX buffer. In the second case, the application task writes message data via UART. Results are being sent to the Usart Terminal where you can track their changes.


void application_task ( void )
{
    canisolator_data_t tmp;

    //  Task implementation.

#ifdef DEMO_APP_RECEIVER

    // RECEIVER - UART polling

    tmp =  canisolator_generic_single_read( &canisolator );
    log_printf( &logger, " %c ", tmp );

#endif
#ifdef DEMO_APP_TRANSMITER

    // TRANSMITER - TX each 2 sec

    uint8_t cnt;

    for ( cnt = 0; cnt < 9; cnt ++ )
    {
        canisolator_generic_single_write( &canisolator, demo_message[ cnt ] );
        Delay_ms ( 100 );
    }

    Delay_ms ( 1000 );
    Delay_ms ( 1000 );

#endif

}

Note

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.CanIsolator

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Current 2 click

8

The Current 2 click is an accurate current sensing Click board suitable for a very accurate measurement of the current through the load. It utilizes the high-side current sensing approach, which has a few advantages over the low-side current sensing.

[Learn More]

XBEE 2 click

0

Xbee 2 Click is a compact add-on board providing wireless end-point connectivity to other devices. This board features the XB3-24Z8UM, a Digi XBee® 3 transceiver module offering a fully interoperable ecosystem covering all vertical markets from Digi International. Building on industry-leading technology, the pre-certified Digi XBee® 3 module delivers the flexibility to switch between multiple frequencies and wireless protocols as needed (Zigbee, 802.15.4, DigiMesh® and BLE). It can be easily configured and controlled from a simple, central platform and comes with built-in Digi TrustFence® security, identity, and data privacy features which use more than 175 controls to protect against new and evolving cyber threats.

[Learn More]

Secure click

1

Secure click carries the ATECC508A cryptographic coprocessor with secure hardware-based key storage. The click is designed to run on either 3.3V or 5V power supply. It communicates with the target microcontroller over I2C interface.

[Learn More]