TOP Contributors

  1. MIKROE (2658 codes)
  2. Alcides Ramos (355 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136935 times)
  2. FAT32 Library (70055 times)
  3. Network Ethernet Library (56013 times)
  4. USB Device Library (46328 times)
  5. Network WiFi Library (41936 times)
  6. FT800 Library (41259 times)
  7. GSM click (29046 times)
  8. mikroSDK (26451 times)
  9. PID Library (26435 times)
  10. microSD click (25391 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Light click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Optical

Downloaded: 109 times

Not followed.

License: MIT license  

This application return the ambient light intensity

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Light click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Light click" changes.

Do you want to report abuse regarding "Light click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Light click

Light click is the add-on board with PD15-22CTR8 PIN photodiode, providing an effective and easy way to measure ambient light intensity.

light_click.png

click Product page


Click library

  • Author : MikroE Team
  • Date : Feb 2020.
  • Type : SPI type

Software Support

We provide a library for the Light Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Light Click driver.

Standard key functions :

  • Config Object Initialization function.

    void light_cfg_setup ( light_cfg_t *cfg );

  • Initialization function.

    LIGHT_RETVAL light_init ( light_t ctx, light_cfg_t cfg );

Example key functions :

  • Generic write data function.

    void light_write_data ( light_t *ctx, uint8_t address, uint8_t write_command );

  • Generic read data function.

    uint16_t light_read_data ( light_t *ctx );

  • Function calculate percent.

    uint8_t light_calculate_percent ( light_t *ctx, uint16_t light_value );

Examples Description

This application return the ambient light intensity.

The demo application is composed of two sections :

Application Init

Initialization driver enable's - SPI and start write log.


void application_init ( void )
{
    log_cfg_t log_cfg;
    light_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    light_cfg_setup( &cfg );
    LIGHT_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    light_init( &light, &cfg );
}

Application Task

This is a example which demonstrates the use of Light Click board. Measured light intensity and calculate light intensity percent from sensor, results are being sent to the Usart Terminal where you can track their changes. All data logs on usb uart for aproximetly every 100 ms when the data value changes.


void application_task ( void )
{
    uint16_t light_value;
    uint8_t light_percent;
    uint8_t percent_old = 1;

    light_value = light_read_data( &light );
    light_percent = light_calculate_percent( &light, light_value );


    if ( percent_old != light_percent )
    {
        log_printf( &logger, " Light Intensity : %d \r\n", light_percent );

        log_printf( &logger, " Light Value     : %d\r\n", light_value );

        percent_old = light_percent;
        Delay_100ms();
    }
    Delay_ms ( 1000 );
}  

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Light

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Rotary B 2 click

0

Rotary B 2 Click is a compact add-on board that allows you to add a precision input knob to your design. This board features the TLC5925, a low-power 16-channel constant-current LED sink driver from Texas Instruments that, combined with a high-quality rotary encoder from ALPS, the EC12D1564402, allows you to add a precision input knob to your design. It also features an LED ring composed of 16 individual blue LEDs that can be used to represent the encoder position more visually.

[Learn More]

TFT Proto 4.3in - Example

1

TFT Proto 4.3in carries a 480x272 ATO43B35 TFT screen covered with a 4-wire resistive touchscreen panel. To drive the 262k-color display, there's an SSD1963 graphic controller. The touchpanel is driven by an advanced STMPE811 controller. Source code examples demonstrate calculator on TFT display.

[Learn More]

DHT22 2 click

0

DHT22 2 click is used for measuring the environmental temperature and relative humidity. It uses the AM2322 sensor, with very accurate thermal and humidity measuring capabilities. It can use either 1-Wire or I2C protocol to communicate with the integrated circuit.

[Learn More]