TOP Contributors

  1. MIKROE (2657 codes)
  2. Alcides Ramos (354 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136900 times)
  2. FAT32 Library (70034 times)
  3. Network Ethernet Library (56005 times)
  4. USB Device Library (46308 times)
  5. Network WiFi Library (41934 times)
  6. FT800 Library (41232 times)
  7. GSM click (29022 times)
  8. PID Library (26434 times)
  9. mikroSDK (26401 times)
  10. microSD click (25387 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Pressure 12 click

Rating:

5

Author: MIKROE

Last Updated: 2019-05-24

Package Version: 1.0.0.0

mikroSDK Library: 1.0.0.0

Category: Pressure

Downloaded: 3384 times

Not followed.

License: MIT license  

Pressure 12 click is a barometric gauge pressure measuring Click board, equipped with the Amplified Basic Pressure sensor series (ABP), which features a ratiometric analog output, which is proportional to the applied pressure.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Pressure 12 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Pressure 12 click" changes.

Do you want to report abuse regarding "Pressure 12 click".

  • mikroSDK Library 2.0.0.0
  • Comments (0)
DOWNLOAD LINK RELATED COMPILER CONTAINS
mikroBasic PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc

mikroSDK Library Blog

Pressure 12 click

Pressure 12 click

Native view of the Pressure 12 click board.

View full image
Pressure 12 click

Pressure 12 click

Front and back view of the Pressure 12 click board.

View full image

Library Description

The library contains all the necessary functions for converting ADC values to real voltages and pressure values.

Key functions:

  • float pressure12_getPressure(uint16_t adcValue) - Convert ADC value to Pressure data in mBar.
  • float pressure12_getVoltage(uint16_t adcValue) - Convert ADC value to Voltage in mV.
  • void pressure12_setMaxVoltage(float volt) - Sets max output voltage on the AN pin.

Examples description

The application is composed of three sections :

  • System Initialization - Initializes LOG for logging data.
  • Application Initialization - ADC init.
  • Application Task - Reads ADC value, Convert ADC data to Voltage[mV] on the AN pin and convert to Pressure data in mBar. All data logs to the USBUART every 1sec.
	void applicationTask()
{
    uint16_t ADC_value;
    float Voltage;
    float Pressure;
    char demoText[ 50 ];

    ADC_value = pressure12_adcRead();
    Voltage = pressure12_getVoltage(ADC_Value);
    Pressure = pressure12_getPressure(ADC_Value);

    WordToStr(ADC_value, demoText);
    mikrobus_logWrite(" ADC value: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_LINE);

    FloatToStr(Voltage, demoText);
    mikrobus_logWrite(" Voltage: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_TEXT );
    mikrobus_logWrite(" mV", _LOG_LINE );

    FloatToStr(Pressure, demoText);
    mikrobus_logWrite(" Pressure: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_TEXT);
    mikrobus_logWrite(" mBar", _LOG_LINE );

    mikrobus_logWrite("--------------------------", _LOG_LINE);
    Delay_ms( 1000 );
}

Other mikroE Libraries used in the example:

  • ADC Library
  • Conversion Library

Additional notes and informations

Depending on the development board you are using, you may need USB UART clickUSB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

Library Description

The library contains all the necessary functions for converting ADC values to real voltages and pressure values.

Key functions:

  • float pressure12_getPressure(uint16_t adcValue) - Convert ADC value to Pressure data in mBar.
  • float pressure12_getVoltage(uint16_t adcValue) - Convert ADC value to Voltage in mV.
  • void pressure12_setMaxVoltage(float volt) - Sets max output voltage on the AN pin.

Examples description

The application is composed of three sections :

  • System Initialization - Initializes LOG for logging data.
  • Application Initialization - ADC init.
  • Application Task - Reads ADC value, Convert ADC data to Voltage[mV] on the AN pin and convert to Pressure data in mBar. All data logs to the USBUART every 1sec.
	void applicationTask()
{
    uint16_t ADC_value;
    float Voltage;
    float Pressure;
    char demoText[ 50 ];

    ADC_value = pressure12_adcRead();
    Voltage = pressure12_getVoltage(ADC_Value);
    Pressure = pressure12_getPressure(ADC_Value);

    WordToStr(ADC_value, demoText);
    mikrobus_logWrite(" ADC value: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_LINE);

    FloatToStr(Voltage, demoText);
    mikrobus_logWrite(" Voltage: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_TEXT );
    mikrobus_logWrite(" mV", _LOG_LINE );

    FloatToStr(Pressure, demoText);
    mikrobus_logWrite(" Pressure: ", _LOG_TEXT);
    mikrobus_logWrite(demoText, _LOG_TEXT);
    mikrobus_logWrite(" mBar", _LOG_LINE );

    mikrobus_logWrite("--------------------------", _LOG_LINE);
    Delay_ms( 1000 );
}

Other mikroE Libraries used in the example:

  • ADC Library
  • Conversion Library

Additional notes and informations

Depending on the development board you are using, you may need USB UART clickUSB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

ALSO FROM THIS AUTHOR

Accel 4 click

0

Accel 4 Click is a compact add-on board that contains an acceleration sensor. This board features the FXLS8964AF, a 12-bit three-axis accelerometer from NXP Semiconductors. It allows selectable full-scale acceleration measurements in ranges of �2g, �4g, �8g, or �16g in three axes with a configurable host interface that supports both SPI and I2C serial communication. The FXLS8964AF supports both high-performance and low-power operating modes, allowing maximum flexibility to meet the resolution and power needs for various unique use cases.

[Learn More]

Thermo 22 click

0

Thermo 22 Click is a compact add-on board that provides an accurate temperature measurement. This board features the TMP75C, a high-precision digital temperature sensor from Texas Instruments. The TMP75C houses an integrated digital temperature sensor with a 12-bit analog-to-digital converter (ADC), a reference circuit, and serial interface logic functions in one package. Characterized by its high accuracy (up to ±0.25°C typical) and high resolution of 0.0625°C, this temperature sensor provides temperature data to the host controller with a configurable I2C interface. This Click board™ is appropriate for thermal management and protection of various consumer, industrial, and environmental applications.

[Learn More]

ANNA-B412 click

0

ANNA-B412 Click is a compact add-on board that provides BT/BLE connectivity for any embedded application. This board features the ANNA-B412, a standalone Bluetooth 5.1 low-energy module from u-blox. It is a System-in-Package (SiP) design with pre-flashed u-connectXpress software, which supports Bluetooth LE Serial port service, GATT client and server, Bluetooth beacons, Bluetooth long-range, NFC, and simultaneous peripheral and central roles. The Bluetooth module in LE mode can achieve up to 2Mbps data rates.

[Learn More]